The Alcatel-Lucent OmniSwitch® 6900 Stackable LAN and data center switches are compact, high-density 10 Gb Ethernet (GigE), 25 GigE, 40 GigE and 100 GigE platforms. In addition to high performance and extremely low latency, they offer Virtual Extensible LAN (VXLAN), OpenFlow, Shortest Path Bridging (SPB), and data center bridging (DCB) capabilities, QoS, Layer-2 and Layer-3 switching, as well as system and network level resiliency. They are designed for the most demanding software-defined operations in virtualized or physical networks and converged data centers.
Feature | Model |
OS6900-X72-R | |
Port count | 72 (48 SFP+ and 6 QSFP) |
Expansion slots | N/A |
Out-of-band Ethernet port | 1 |
USB port | 1 |
Console port | 1 |
Primary slide-in PSU slot | 1 |
Backup slide-in PSU slot | 1 |
Redundant fans | 3+1 |
Flash | 4 GB |
RAM | 8 GB |
Data buffer | 12 MB |
Max switching capacity | 1.44 Tb/s Non-blocking |
Throughput | 1000 Mpps |
Latency | <650ns |
Power consumption | 242 W |
Heat dissipation | 825 Btu/h |
Mean time between failures (MTBF) with AC power supply | 192,778 h |
MTBF with DC power supply | 206,968 h |
Width | 43.3 cm (17.06 in) |
Depth | 55.9 cm (22.00 in.) |
Height | 4.4 cm (1.73 in.) |
Weight (chassis & fan) | 7.78 kg (17.15 lb) |
Weight (fully populated) | 10.86 kg (23.95 lb) |
Operating temperature Front-to-rear airflow | 0°C to 45°C (32°F to 113°F) 55°C shutdown |
Operating temperature Rear-to-front airflow | 0°C to 45°C (32°F to 113°F) 55°C shutdown |
Storage temperature | -10°C to 70°C (14°F to 158°F) |
Humidity (operating) | 5% to 95% non-condensing |
Humidity (storage) | 5% to 95% non-condensing |
The Alcatel-Lucent OmniSwitch® 6900 Stackable LAN and data center switches are compact, high-density 10 Gb Ethernet (GigE), 25 GigE, 40 GigE and 100 GigE platforms. In addition to high performance and extremely low latency, they offer Virtual Extensible LAN (VXLAN), OpenFlow, Shortest Path Bridging (SPB), and data center bridging (DCB) capabilities, QoS, Layer-2 and Layer-3 switching, as well as system and network level resiliency. They are designed for the most demanding software-defined operations in virtualized or physical networks and converged data centers.
Feature | Model |
OS6900-X72-R | |
Port count | 72 (48 SFP+ and 6 QSFP) |
Expansion slots | N/A |
Out-of-band Ethernet port | 1 |
USB port | 1 |
Console port | 1 |
Primary slide-in PSU slot | 1 |
Backup slide-in PSU slot | 1 |
Redundant fans | 3+1 |
Flash | 4 GB |
RAM | 8 GB |
Data buffer | 12 MB |
Max switching capacity | 1.44 Tb/s Non-blocking |
Throughput | 1000 Mpps |
Latency | <650ns |
Power consumption | 242 W |
Heat dissipation | 825 Btu/h |
Mean time between failures (MTBF) with AC power supply | 192,778 h |
MTBF with DC power supply | 206,968 h |
Width | 43.3 cm (17.06 in) |
Depth | 55.9 cm (22.00 in.) |
Height | 4.4 cm (1.73 in.) |
Weight (chassis & fan) | 7.78 kg (17.15 lb) |
Weight (fully populated) | 10.86 kg (23.95 lb) |
Operating temperature Front-to-rear airflow | 0°C to 45°C (32°F to 113°F) 55°C shutdown |
Operating temperature Rear-to-front airflow | 0°C to 45°C (32°F to 113°F) 55°C shutdown |
Storage temperature | -10°C to 70°C (14°F to 158°F) |
Humidity (operating) | 5% to 95% non-condensing |
Humidity (storage) | 5% to 95% non-condensing |